Area of Filter given Organic Loading Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length)
A = BOD5/(OL*Lf)
This formula uses 4 Variables
Variables Used
Area of Filter - (Measured in Square Meter) - The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²).
BOD Loading to Filter - (Measured in Kilogram per Second) - BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume.
Organic Loading - (Measured in Kilogram per Second Square Meter) - Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater.
Filter Length - (Measured in Meter) - The Filter Length refers to the total length of filter required to effectively do the filtering process.
STEP 1: Convert Input(s) to Base Unit
BOD Loading to Filter: 225 Kilogram per Day --> 0.00260416666666667 Kilogram per Second (Check conversion ​here)
Organic Loading: 30 kilogram per Day Square Meter --> 0.000347222222222222 Kilogram per Second Square Meter (Check conversion ​here)
Filter Length: 2.5 Meter --> 2.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = BOD5/(OL*Lf) --> 0.00260416666666667/(0.000347222222222222*2.5)
Evaluating ... ...
A = 3.00000000000001
STEP 3: Convert Result to Output's Unit
3.00000000000001 Square Meter --> No Conversion Required
FINAL ANSWER
3.00000000000001 3 Square Meter <-- Area of Filter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Organic Loading Calculators

Organic Loading to Trickling Filter
​ LaTeX ​ Go Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length))
Area of Filter given Organic Loading
​ LaTeX ​ Go Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length)
Filter Length given Organic Loading
​ LaTeX ​ Go Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter)
BOD Load given Organic Loading
​ LaTeX ​ Go BOD Loading to Filter = Organic Loading*Area of Filter*Filter Length

Area of Filter given Organic Loading Formula

​LaTeX ​Go
Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length)
A = BOD5/(OL*Lf)

What is Organic Loading Rate ?

Organic Loading Rate is defined as the application of soluble and particulate organic matter. It is typically expressed on an area basis as pounds of BOD5 per unit area per unit time, such as pounds of BOD5 per square foot per day (lb/ft2/day).

How to Calculate Area of Filter given Organic Loading?

Area of Filter given Organic Loading calculator uses Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length) to calculate the Area of Filter, The Area of Filter given Organic Loading is defined as the surface area required for a filtration system, determined by the organic loading rate and desired treatment efficiency. Area of Filter is denoted by A symbol.

How to calculate Area of Filter given Organic Loading using this online calculator? To use this online calculator for Area of Filter given Organic Loading, enter BOD Loading to Filter (BOD5), Organic Loading (OL) & Filter Length (Lf) and hit the calculate button. Here is how the Area of Filter given Organic Loading calculation can be explained with given input values -> 2.5 = 0.00260416666666667/(0.000347222222222222*2.5).

FAQ

What is Area of Filter given Organic Loading?
The Area of Filter given Organic Loading is defined as the surface area required for a filtration system, determined by the organic loading rate and desired treatment efficiency and is represented as A = BOD5/(OL*Lf) or Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length). BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume, Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater & The Filter Length refers to the total length of filter required to effectively do the filtering process.
How to calculate Area of Filter given Organic Loading?
The Area of Filter given Organic Loading is defined as the surface area required for a filtration system, determined by the organic loading rate and desired treatment efficiency is calculated using Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length). To calculate Area of Filter given Organic Loading, you need BOD Loading to Filter (BOD5), Organic Loading (OL) & Filter Length (Lf). With our tool, you need to enter the respective value for BOD Loading to Filter, Organic Loading & Filter Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!