Area of Core given EMF Induced in Secondary Winding Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density)
Acore = E2/(4.44*f*N2*Bmax)
This formula uses 5 Variables
Variables Used
Area of Core - (Measured in Square Meter) - Area of Core is defined as the space occupied by the core of a transformer in 2 dimensional space.
EMF Induced in Secondary - (Measured in Volt) - EMF Induced in Secondary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil.
Supply Frequency - (Measured in Hertz) - Supply Frequency means Induction motors are designed for a specific voltage per frequency ratio (V/Hz). The voltage is called the supply voltage and the frequency is called the 'Supply Frequency'.
Number of Turns in Secondary - The Number of Turns in Secondary Winding is the number of turns secondary winding is the winding of a transformer.
Maximum Flux Density - (Measured in Tesla) - Maximum Flux Density is defined as the number of lines of force passing through a unit area of material.
STEP 1: Convert Input(s) to Base Unit
EMF Induced in Secondary: 15.84 Volt --> 15.84 Volt No Conversion Required
Supply Frequency: 500 Hertz --> 500 Hertz No Conversion Required
Number of Turns in Secondary: 24 --> No Conversion Required
Maximum Flux Density: 0.0012 Tesla --> 0.0012 Tesla No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Acore = E2/(4.44*f*N2*Bmax) --> 15.84/(4.44*500*24*0.0012)
Evaluating ... ...
Acore = 0.247747747747748
STEP 3: Convert Result to Output's Unit
0.247747747747748 Square Meter -->2477.47747747748 Square Centimeter (Check conversion ​here)
FINAL ANSWER
2477.47747747748 2477.477 Square Centimeter <-- Area of Core
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Transformer Design Calculators

Area of Core given EMF Induced in Secondary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density)
Area of Core given EMF Induced in Primary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary*Maximum Flux Density)
Maximum Flux in Core using Primary Winding
​ LaTeX ​ Go Maximum Core Flux = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary)
Maximum Core Flux
​ LaTeX ​ Go Maximum Core Flux = Maximum Flux Density*Area of Core

Mechanical Specifications Calculators

Area of Core given EMF Induced in Secondary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density)
Number of Turns in Secondary Winding
​ LaTeX ​ Go Number of Turns in Secondary = EMF Induced in Secondary/(4.44*Supply Frequency*Area of Core*Maximum Flux Density)
Area of Core given EMF Induced in Primary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary*Maximum Flux Density)
Number of Turns in Primary Winding
​ LaTeX ​ Go Number of Turns in Primary = EMF Induced in Primary/(4.44*Supply Frequency*Area of Core*Maximum Flux Density)

Area of Core given EMF Induced in Secondary Winding Formula

​LaTeX ​Go
Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density)
Acore = E2/(4.44*f*N2*Bmax)

What is induced EMF?

Alternating flux gets linked with the secondary winding, and because of the phenomenon of mutual induction, an emf gets induced in the secondary winding. The magnitude of this induced emf can be found by using the following EMF equation of the transformer.

How to Calculate Area of Core given EMF Induced in Secondary Winding?

Area of Core given EMF Induced in Secondary Winding calculator uses Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density) to calculate the Area of Core, Area of Core given EMF Induced in Secondary Winding formula is defined as the amount of two-dimensional space taken up by an object. The magnitude of this induced emf can be found by using the following EMF equation of the transformer. Area of Core is denoted by Acore symbol.

How to calculate Area of Core given EMF Induced in Secondary Winding using this online calculator? To use this online calculator for Area of Core given EMF Induced in Secondary Winding, enter EMF Induced in Secondary (E2), Supply Frequency (f), Number of Turns in Secondary (N2) & Maximum Flux Density (Bmax) and hit the calculate button. Here is how the Area of Core given EMF Induced in Secondary Winding calculation can be explained with given input values -> 2.5E+7 = 15.84/(4.44*500*24*0.0012).

FAQ

What is Area of Core given EMF Induced in Secondary Winding?
Area of Core given EMF Induced in Secondary Winding formula is defined as the amount of two-dimensional space taken up by an object. The magnitude of this induced emf can be found by using the following EMF equation of the transformer and is represented as Acore = E2/(4.44*f*N2*Bmax) or Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density). EMF Induced in Secondary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil, Supply Frequency means Induction motors are designed for a specific voltage per frequency ratio (V/Hz). The voltage is called the supply voltage and the frequency is called the 'Supply Frequency', The Number of Turns in Secondary Winding is the number of turns secondary winding is the winding of a transformer & Maximum Flux Density is defined as the number of lines of force passing through a unit area of material.
How to calculate Area of Core given EMF Induced in Secondary Winding?
Area of Core given EMF Induced in Secondary Winding formula is defined as the amount of two-dimensional space taken up by an object. The magnitude of this induced emf can be found by using the following EMF equation of the transformer is calculated using Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density). To calculate Area of Core given EMF Induced in Secondary Winding, you need EMF Induced in Secondary (E2), Supply Frequency (f), Number of Turns in Secondary (N2) & Maximum Flux Density (Bmax). With our tool, you need to enter the respective value for EMF Induced in Secondary, Supply Frequency, Number of Turns in Secondary & Maximum Flux Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Area of Core?
In this formula, Area of Core uses EMF Induced in Secondary, Supply Frequency, Number of Turns in Secondary & Maximum Flux Density. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Area of Core = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary*Maximum Flux Density)
  • Area of Core = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary*Maximum Flux Density)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!