Aquifer Thickness given Discharge for Partially Penetrating Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
b = Qv/((2*pi*K*(H-hw)*G)/(log((R/r),e)))
This formula uses 2 Constants, 1 Functions, 8 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Discharge for Partially Penetrating Well - (Measured in Cubic Meter per Second) - Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Coefficient of Permeability - (Measured in Meter per Second) - Coefficient of Permeability refers to the ease with which water can flow through the aquifer's pore spaces.
Initial Piezometric Surface - (Measured in Meter) - The initial piezometric surface refers to the level at which groundwater naturally stands in a confined aquifer before any pumping or external influence.
Depth of Water - (Measured in Meter) - Depth of Water is the depth in the well measured above the impermeable layer.
Correction Factor - Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
Radius of Influence - (Measured in Meter) - The radius of influence is the distance from a pumping well to the point where the drawdown, or lowering of the water table, becomes negligible.
Radius of Well - (Measured in Meter) - The radius of well refers to the horizontal distance from the center of the well to its inner wall, essentially the well’s radius.
STEP 1: Convert Input(s) to Base Unit
Discharge for Partially Penetrating Well: 5.08 Cubic Meter per Second --> 5.08 Cubic Meter per Second No Conversion Required
Coefficient of Permeability: 0.105 Centimeter per Second --> 0.00105 Meter per Second (Check conversion ​here)
Initial Piezometric Surface: 20 Meter --> 20 Meter No Conversion Required
Depth of Water: 2.44 Meter --> 2.44 Meter No Conversion Required
Correction Factor: 0.83 --> No Conversion Required
Radius of Influence: 100 Meter --> 100 Meter No Conversion Required
Radius of Well: 2.94 Meter --> 2.94 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
b = Qv/((2*pi*K*(H-hw)*G)/(log((R/r),e))) --> 5.08/((2*pi*0.00105*(20-2.44)*0.83)/(log((100/2.94),e)))
Evaluating ... ...
b = 14.9801430298163
STEP 3: Convert Result to Output's Unit
14.9801430298163 Meter --> No Conversion Required
FINAL ANSWER
14.9801430298163 14.98014 Meter <-- Aquifer Thickness
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Partially Penetrating Artesian Well Calculators

Coefficient of Permeability given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Coefficient of Permeability = Discharge for Partially Penetrating Well/((2*pi*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Aquifer Thickness given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Thickness of Aquifer given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Initial Piezometric Surface = Depth of Water+(Discharge for Partially Penetrating Well*(log((Radius of Influence/Radius of Well),e)))/(2*pi*Coefficient of Permeability*Aquifer Thickness*Correction Factor)
Discharge for Partially Penetrating Well
​ LaTeX ​ Go Discharge for Partially Penetrating Well = (2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))

Aquifer Thickness given Discharge for Partially Penetrating Well Formula

​LaTeX ​Go
Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
b = Qv/((2*pi*K*(H-hw)*G)/(log((R/r),e)))

What is Aquifer?

An aquifer is a body of rock and/or sediment that holds groundwater. Groundwater is the word used to describe precipitation that has infiltrated the soil beyond the surface and collected in empty spaces underground.

How to Calculate Aquifer Thickness given Discharge for Partially Penetrating Well?

Aquifer Thickness given Discharge for Partially Penetrating Well calculator uses Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))) to calculate the Aquifer Thickness, Aquifer Thickness given Discharge for Partially Penetrating Well formula is defined as a measure of the thickness of an aquifer when a partially penetrating well is pumping water, taking into account the discharge rate, hydraulic conductivity, and other relevant factors, providing valuable insights into groundwater flow and management. Aquifer Thickness is denoted by b symbol.

How to calculate Aquifer Thickness given Discharge for Partially Penetrating Well using this online calculator? To use this online calculator for Aquifer Thickness given Discharge for Partially Penetrating Well, enter Discharge for Partially Penetrating Well (Qv), Coefficient of Permeability (K), Initial Piezometric Surface (H), Depth of Water (hw), Correction Factor (G), Radius of Influence (R) & Radius of Well (r) and hit the calculate button. Here is how the Aquifer Thickness given Discharge for Partially Penetrating Well calculation can be explained with given input values -> 14.98014 = 5.08/((2*pi*0.00105*(20-2.44)*0.83)/(log((100/2.94),e))).

FAQ

What is Aquifer Thickness given Discharge for Partially Penetrating Well?
Aquifer Thickness given Discharge for Partially Penetrating Well formula is defined as a measure of the thickness of an aquifer when a partially penetrating well is pumping water, taking into account the discharge rate, hydraulic conductivity, and other relevant factors, providing valuable insights into groundwater flow and management and is represented as b = Qv/((2*pi*K*(H-hw)*G)/(log((R/r),e))) or Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))). Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer, Coefficient of Permeability refers to the ease with which water can flow through the aquifer's pore spaces, The initial piezometric surface refers to the level at which groundwater naturally stands in a confined aquifer before any pumping or external influence, Depth of Water is the depth in the well measured above the impermeable layer, Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness, The radius of influence is the distance from a pumping well to the point where the drawdown, or lowering of the water table, becomes negligible & The radius of well refers to the horizontal distance from the center of the well to its inner wall, essentially the well’s radius.
How to calculate Aquifer Thickness given Discharge for Partially Penetrating Well?
Aquifer Thickness given Discharge for Partially Penetrating Well formula is defined as a measure of the thickness of an aquifer when a partially penetrating well is pumping water, taking into account the discharge rate, hydraulic conductivity, and other relevant factors, providing valuable insights into groundwater flow and management is calculated using Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))). To calculate Aquifer Thickness given Discharge for Partially Penetrating Well, you need Discharge for Partially Penetrating Well (Qv), Coefficient of Permeability (K), Initial Piezometric Surface (H), Depth of Water (hw), Correction Factor (G), Radius of Influence (R) & Radius of Well (r). With our tool, you need to enter the respective value for Discharge for Partially Penetrating Well, Coefficient of Permeability, Initial Piezometric Surface, Depth of Water, Correction Factor, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!