Aquifer Thickness when Transmissivity of Aquifer is Considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Thickness = Transmissivity/Equivalent Permeability
b = τ/Ke
This formula uses 3 Variables
Variables Used
Aquifer Thickness - (Measured in Meter) - The Aquifer Thickness is referred as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters.
Transmissivity - (Measured in Square Meter per Second) - The Transmissivity refers to the measure of how much water can be transmitted horizontally through an aquifer is the product of the hydraulic conductivity of the aquifer and its saturated thickness.
Equivalent Permeability - (Measured in Meter per Second) - The Equivalent Permeability is referred as when the flow is parallel to stratification.
STEP 1: Convert Input(s) to Base Unit
Transmissivity: 1.4 Square Meter per Second --> 1.4 Square Meter per Second No Conversion Required
Equivalent Permeability: 4 Centimeter per Second --> 0.04 Meter per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
b = τ/Ke --> 1.4/0.04
Evaluating ... ...
b = 35
STEP 3: Convert Result to Output's Unit
35 Meter --> No Conversion Required
FINAL ANSWER
35 Meter <-- Aquifer Thickness
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Transmissivity of Aquifer Calculators

Transmissivity given Discharge Quantity
​ LaTeX ​ Go Transmissivity = (Total Water Volume/Aquifer Thickness)*(Distance Between the Points/Change in Head Between the Points)
Quantity of Water for Transmissivity
​ LaTeX ​ Go Total Water Volume = Transmissivity*Aquifer Thickness*Hydraulic Gradient
Transmissibility when Coefficient of Permeability is Considered
​ LaTeX ​ Go Transmissivity = Coefficient of Permeability at 20° C*Aquifer Thickness
Unit Dimension of Aquifer about Transmissivity
​ LaTeX ​ Go Aquifer Thickness = Transmissivity/Coefficient of Permeability at 20° C

Aquifer Thickness when Transmissivity of Aquifer is Considered Formula

​LaTeX ​Go
Aquifer Thickness = Transmissivity/Equivalent Permeability
b = τ/Ke

What is Aquifer Transmissivity?

Transmissivity describes the ability of the aquifer to transmit groundwater throughout its entire saturated thickness. Transmissivity is measured as the rate at which groundwater can flow through an aquifer section of unit width under a unit hydraulic gradient.

How to Calculate Aquifer Thickness when Transmissivity of Aquifer is Considered?

Aquifer Thickness when Transmissivity of Aquifer is Considered calculator uses Aquifer Thickness = Transmissivity/Equivalent Permeability to calculate the Aquifer Thickness, The Aquifer Thickness when Transmissivity of Aquifer is Considered formula is defined as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters. Aquifer Thickness is denoted by b symbol.

How to calculate Aquifer Thickness when Transmissivity of Aquifer is Considered using this online calculator? To use this online calculator for Aquifer Thickness when Transmissivity of Aquifer is Considered, enter Transmissivity (τ) & Equivalent Permeability (Ke) and hit the calculate button. Here is how the Aquifer Thickness when Transmissivity of Aquifer is Considered calculation can be explained with given input values -> 35 = 1.4/0.04.

FAQ

What is Aquifer Thickness when Transmissivity of Aquifer is Considered?
The Aquifer Thickness when Transmissivity of Aquifer is Considered formula is defined as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters and is represented as b = τ/Ke or Aquifer Thickness = Transmissivity/Equivalent Permeability. The Transmissivity refers to the measure of how much water can be transmitted horizontally through an aquifer is the product of the hydraulic conductivity of the aquifer and its saturated thickness & The Equivalent Permeability is referred as when the flow is parallel to stratification.
How to calculate Aquifer Thickness when Transmissivity of Aquifer is Considered?
The Aquifer Thickness when Transmissivity of Aquifer is Considered formula is defined as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters is calculated using Aquifer Thickness = Transmissivity/Equivalent Permeability. To calculate Aquifer Thickness when Transmissivity of Aquifer is Considered, you need Transmissivity (τ) & Equivalent Permeability (Ke). With our tool, you need to enter the respective value for Transmissivity & Equivalent Permeability and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Aquifer Thickness?
In this formula, Aquifer Thickness uses Transmissivity & Equivalent Permeability. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Aquifer Thickness = Transmissivity/Coefficient of Permeability at 20° C