Aquifer Thickness given Confined Aquifer Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
bw = Q/((2*pi*KWH*st)/(log((Rw/r),e)))
This formula uses 2 Constants, 1 Functions, 6 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the flow rate of water that is extracted from or injected into a well.
Coefficient of Permeability in Well Hydraulics - (Measured in Meter per Second) - Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Total Drawdown - (Measured in Meter) - The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of Well - (Measured in Meter) - Radius of Well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Coefficient of Permeability in Well Hydraulics: 10 Centimeter per Second --> 0.1 Meter per Second (Check conversion ​here)
Total Drawdown: 0.83 Meter --> 0.83 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of Well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
bw = Q/((2*pi*KWH*st)/(log((Rw/r),e))) --> 1.01/((2*pi*0.1*0.83)/(log((8.6/7.5),e)))
Evaluating ... ...
bw = 14.1510762430351
STEP 3: Convert Result to Output's Unit
14.1510762430351 Meter --> No Conversion Required
FINAL ANSWER
14.1510762430351 14.15108 Meter <-- Aquifer Thickness
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Aquifer Thickness Calculators

Thickness of Confined Aquifer given Discharge in Confined Aquifer
​ LaTeX ​ Go Aquifer Thickness During Pumping = Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e)))
Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10
​ LaTeX ​ Go Aquifer Thickness given Confined Aquifer Discharge = Discharge in Confined Aquifer/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer
​ LaTeX ​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of Well),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer with Base 10
​ LaTeX ​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of Well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness))

Aquifer Thickness given Confined Aquifer Discharge Formula

​LaTeX ​Go
Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
bw = Q/((2*pi*KWH*st)/(log((Rw/r),e)))

What is Aquifer?

An aquifer is an underground layer of water-bearing permeable rock, rock fractures or unconsolidated materials (gravel, sand, or silt). Groundwater can be extracted using a water well. The study of water flow in aquifers and the characterization of aquifers is called hydrogeology.

How to Calculate Aquifer Thickness given Confined Aquifer Discharge?

Aquifer Thickness given Confined Aquifer Discharge calculator uses Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))) to calculate the Aquifer Thickness, The Aquifer Thickness given Confined Aquifer Discharge formula is defined as the value of thickness of an aquifer, which is the water-bearing layer of permeable rock, sand, or gravel, measured from the base of an impermeable layer above or below the aquifer, when we have prior information of confined aquifer discharge. Aquifer Thickness is denoted by bw symbol.

How to calculate Aquifer Thickness given Confined Aquifer Discharge using this online calculator? To use this online calculator for Aquifer Thickness given Confined Aquifer Discharge, enter Discharge (Q), Coefficient of Permeability in Well Hydraulics (KWH), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button. Here is how the Aquifer Thickness given Confined Aquifer Discharge calculation can be explained with given input values -> 14.15108 = 1.01/((2*pi*0.1*0.83)/(log((8.6/7.5),e))).

FAQ

What is Aquifer Thickness given Confined Aquifer Discharge?
The Aquifer Thickness given Confined Aquifer Discharge formula is defined as the value of thickness of an aquifer, which is the water-bearing layer of permeable rock, sand, or gravel, measured from the base of an impermeable layer above or below the aquifer, when we have prior information of confined aquifer discharge and is represented as bw = Q/((2*pi*KWH*st)/(log((Rw/r),e))) or Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). Discharge is the flow rate of water that is extracted from or injected into a well, Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil, The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of Well is defined as the distance from center of well to its outer boundary.
How to calculate Aquifer Thickness given Confined Aquifer Discharge?
The Aquifer Thickness given Confined Aquifer Discharge formula is defined as the value of thickness of an aquifer, which is the water-bearing layer of permeable rock, sand, or gravel, measured from the base of an impermeable layer above or below the aquifer, when we have prior information of confined aquifer discharge is calculated using Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). To calculate Aquifer Thickness given Confined Aquifer Discharge, you need Discharge (Q), Coefficient of Permeability in Well Hydraulics (KWH), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r). With our tool, you need to enter the respective value for Discharge, Coefficient of Permeability in Well Hydraulics, Total Drawdown, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!