Allowable Unit Load for Hemlock Lumber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4)
Q|A = 700*(1-0.00000097*(L/d)^4)
This formula uses 3 Variables
Variables Used
Allowable Unit Load - (Measured in Newton per Square Millimeter) - Allowable unit load is the maximum load that can be given on the cross-section or lumber in timber.
Length of Column - (Measured in Meter) - Length of Column is the distance between two points where a column gets its fixity of support so its movement is restrained in all directions.
Least Dimension - (Measured in Meter) - Least Dimension is the measure of the shortest side of the column.
STEP 1: Convert Input(s) to Base Unit
Length of Column: 5000 Millimeter --> 5 Meter (Check conversion ​here)
Least Dimension: 200 Millimeter --> 0.2 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q|A = 700*(1-0.00000097*(L/d)^4) --> 700*(1-0.00000097*(5/0.2)^4)
Evaluating ... ...
Q|A = 434.765625
STEP 3: Convert Result to Output's Unit
434765625 Pascal -->434.765625 Megapascal (Check conversion ​here)
FINAL ANSWER
434.765625 434.7656 Megapascal <-- Allowable Unit Load
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Solid Rectangular or Square Columns with Flat Ends Calculators

Allowable Unit Load for Longleaf Yellow Pine Lumber
​ LaTeX ​ Go Allowable Unit Load = 1450*(1-0.00000162*(Length of Column/Least Dimension)^4)
Allowable Unit Load for Southern Cypress Lumber
​ LaTeX ​ Go Allowable Unit Load = 1100*(1-0.00000168*(Length of Column/Least Dimension)^4)
Allowable Unit Load for Douglas Fir Lumber
​ LaTeX ​ Go Allowable Unit Load = 1200*(1-0.00000112*(Length of Column/Least Dimension)^4)
Allowable Unit Load for Hemlock Lumber
​ LaTeX ​ Go Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4)

Allowable Unit Load for Hemlock Lumber Formula

​LaTeX ​Go
Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4)
Q|A = 700*(1-0.00000097*(L/d)^4)

What is Hemlock Lumber?

A little stronger than Pine, Hemlock is a creamy grey colored timber which is ideal for painting, varnishing or polishing. It has relatively good in strength and also know for excellent working with good machining qualities. Commonly used for interior wood working, doors, windows, ceilings and ladders.

What is Allowable Load?

The load induces the maximum permissible unit stress at a critical section of a structural member or timber member.

How to Calculate Allowable Unit Load for Hemlock Lumber?

Allowable Unit Load for Hemlock Lumber calculator uses Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4) to calculate the Allowable Unit Load, The Allowable Unit Load for Hemlock Lumber formula is defined as the maximum allowable load taken by the hemlock lumber cross-section. Allowable Unit Load is denoted by Q|A symbol.

How to calculate Allowable Unit Load for Hemlock Lumber using this online calculator? To use this online calculator for Allowable Unit Load for Hemlock Lumber, enter Length of Column (L) & Least Dimension (d) and hit the calculate button. Here is how the Allowable Unit Load for Hemlock Lumber calculation can be explained with given input values -> 0.000435 = 700*(1-0.00000097*(5/0.2)^4).

FAQ

What is Allowable Unit Load for Hemlock Lumber?
The Allowable Unit Load for Hemlock Lumber formula is defined as the maximum allowable load taken by the hemlock lumber cross-section and is represented as Q|A = 700*(1-0.00000097*(L/d)^4) or Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4). Length of Column is the distance between two points where a column gets its fixity of support so its movement is restrained in all directions & Least Dimension is the measure of the shortest side of the column.
How to calculate Allowable Unit Load for Hemlock Lumber?
The Allowable Unit Load for Hemlock Lumber formula is defined as the maximum allowable load taken by the hemlock lumber cross-section is calculated using Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4). To calculate Allowable Unit Load for Hemlock Lumber, you need Length of Column (L) & Least Dimension (d). With our tool, you need to enter the respective value for Length of Column & Least Dimension and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Allowable Unit Load?
In this formula, Allowable Unit Load uses Length of Column & Least Dimension. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Allowable Unit Load = 1450*(1-0.00000162*(Length of Column/Least Dimension)^4)
  • Allowable Unit Load = 1100*(1-0.00000168*(Length of Column/Least Dimension)^4)
  • Allowable Unit Load = 1200*(1-0.00000112*(Length of Column/Least Dimension)^4)