How to Calculate Allowable Load in Parallel Fillet Weld per Unit Length?
Allowable Load in Parallel Fillet Weld per Unit Length calculator uses Allowable Load Per Unit Length of Weld = 0.707*Shear Stress in Parallel Fillet Weld*Leg of Weld to calculate the Allowable Load Per Unit Length of Weld, Allowable Load in Parallel Fillet Weld per Unit Length is defined as the maximum amount of load that a parallel fillet weld can carry per mm length of the weld. Allowable Load Per Unit Length of Weld is denoted by Pa symbol.
How to calculate Allowable Load in Parallel Fillet Weld per Unit Length using this online calculator? To use this online calculator for Allowable Load in Parallel Fillet Weld per Unit Length, enter Shear Stress in Parallel Fillet Weld (𝜏) & Leg of Weld (hl) and hit the calculate button. Here is how the Allowable Load in Parallel Fillet Weld per Unit Length calculation can be explained with given input values -> 0.569559 = 0.707*38000000*0.0212.