How to Calculate Allowable Bearing Stress in Local Zone?
Allowable Bearing Stress in Local Zone calculator uses Allowable Bearing Stress in Members = 0.48*Cube Strength*sqrt(Bearing Area Between Screw and Nut/Punching Area) to calculate the Allowable Bearing Stress in Members, The Allowable Bearing Stress in Local Zone formula is defined as the maximum stress that can be safely applied to a structure. Allowable Bearing Stress in Members is denoted by Fp symbol.
How to calculate Allowable Bearing Stress in Local Zone using this online calculator? To use this online calculator for Allowable Bearing Stress in Local Zone, enter Cube Strength (fci), Bearing Area Between Screw and Nut (Ab) & Punching Area (Apun) and hit the calculate button. Here is how the Allowable Bearing Stress in Local Zone calculation can be explained with given input values -> 2.6E-7 = 0.48*15500000*sqrt(3E-05/0.008).