Allowable Bearing Pressure given Area of Lowest Column of Structure Solution

STEP 0: Pre-Calculation Summary
Formula Used
Allowable Bearing Pressure = Columns Axial Load/Area of Foundation
Fp = P/A
This formula uses 3 Variables
Variables Used
Allowable Bearing Pressure - (Measured in Megapascal) - Allowable Bearing Pressure is defined as the maximum soil pressure without any shear failure or settlement failure.
Columns Axial Load - (Measured in Newton) - Columns Axial Load is defined as the applying a force on a column structure directly along an axis.
Area of Foundation - (Measured in Square Meter) - Area of Foundation is the horizontal surface on which a building or structure rests to distribute its weight evenly.
STEP 1: Convert Input(s) to Base Unit
Columns Axial Load: 59.5 Newton --> 59.5 Newton No Conversion Required
Area of Foundation: 3.5 Square Meter --> 3.5 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Fp = P/A --> 59.5/3.5
Evaluating ... ...
Fp = 17
STEP 3: Convert Result to Output's Unit
17000000 Pascal -->17 Megapascal (Check conversion ​here)
FINAL ANSWER
17 Megapascal <-- Allowable Bearing Pressure
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has verified this Calculator and 100+ more calculators!

Allowable Stress Design Approach (AISC) Calculators

Allowable Bearing Pressure given Area of Lowest Column of Structure
​ LaTeX ​ Go Allowable Bearing Pressure = Columns Axial Load/Area of Foundation
Area of Foundation of Lowest Column of Structure
​ LaTeX ​ Go Area of Foundation = Columns Axial Load/Allowable Bearing Pressure
Load using Area of Lowest Column of Structure
​ LaTeX ​ Go Columns Axial Load = Allowable Bearing Pressure*Area of Foundation
Allowable Bearing Pressure when Full Area of Support is Occupied by Base Plate
​ LaTeX ​ Go Allowable Bearing Pressure = 0.35*28-Day Compressive Strength of Concrete

Allowable Bearing Pressure given Area of Lowest Column of Structure Formula

​LaTeX ​Go
Allowable Bearing Pressure = Columns Axial Load/Area of Foundation
Fp = P/A

What is the significance of Base Plate in Foundation?

The eccentricity of loading or the presence of bending moment at the column base increases the pressure on some parts of the base plate and decreases it on other parts. To compute these effects, the base plate may be assumed completely rigid so that the pressure variation on the concrete is linear.

What is Allowable Bearing Pressure?

Allowable bearing pressure shall be considered to be the pressure at the base of a foundation in excess of the effective stress existing at the same level prior to construction operations. The allowable pressure depends on the strength of the concrete in the foundation and the relative sizes of a base plate and concrete support area.

How to Calculate Allowable Bearing Pressure given Area of Lowest Column of Structure?

Allowable Bearing Pressure given Area of Lowest Column of Structure calculator uses Allowable Bearing Pressure = Columns Axial Load/Area of Foundation to calculate the Allowable Bearing Pressure, The Allowable Bearing Pressure given Area of Lowest Column of Structure formula is defined as maximum load that footing can support without failure with appropriate factors of safety and maximum load that footing can support without intolerable settlements. Allowable Bearing Pressure is denoted by Fp symbol.

How to calculate Allowable Bearing Pressure given Area of Lowest Column of Structure using this online calculator? To use this online calculator for Allowable Bearing Pressure given Area of Lowest Column of Structure, enter Columns Axial Load (P) & Area of Foundation (A) and hit the calculate button. Here is how the Allowable Bearing Pressure given Area of Lowest Column of Structure calculation can be explained with given input values -> 1.7E-5 = 59.5/3.5.

FAQ

What is Allowable Bearing Pressure given Area of Lowest Column of Structure?
The Allowable Bearing Pressure given Area of Lowest Column of Structure formula is defined as maximum load that footing can support without failure with appropriate factors of safety and maximum load that footing can support without intolerable settlements and is represented as Fp = P/A or Allowable Bearing Pressure = Columns Axial Load/Area of Foundation. Columns Axial Load is defined as the applying a force on a column structure directly along an axis & Area of Foundation is the horizontal surface on which a building or structure rests to distribute its weight evenly.
How to calculate Allowable Bearing Pressure given Area of Lowest Column of Structure?
The Allowable Bearing Pressure given Area of Lowest Column of Structure formula is defined as maximum load that footing can support without failure with appropriate factors of safety and maximum load that footing can support without intolerable settlements is calculated using Allowable Bearing Pressure = Columns Axial Load/Area of Foundation. To calculate Allowable Bearing Pressure given Area of Lowest Column of Structure, you need Columns Axial Load (P) & Area of Foundation (A). With our tool, you need to enter the respective value for Columns Axial Load & Area of Foundation and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Allowable Bearing Pressure?
In this formula, Allowable Bearing Pressure uses Columns Axial Load & Area of Foundation. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Allowable Bearing Pressure = 0.35*28-Day Compressive Strength of Concrete
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!