Adjusted Design Value for Lateral Loading for Spike Grids Solution

STEP 0: Pre-Calculation Summary
Formula Used
Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*Geometry Factor
Z' = Z*CD*Cm*Ct*CΔ
This formula uses 6 Variables
Variables Used
Adjusted Design Value for Lateral Loading - (Measured in Newton) - Adjusted design value for lateral loading is given in terms of nominal design values and adjustment factors.
Nominal Design Value for Lateral Loading - (Measured in Newton) - Nominal Design Value for Lateral Loading for connections or wood members with fasteners. Design values are principles or beliefs that are adopted by a designer to guide their work.
Load Duration Factor - Load Duration Factor is based on the ability of wood to recover after a reasonable load has been applied for a given time.
Wet Service Factor - Wet Service Factor is used to signify wood that will not be used in a dry condition.
Temperature Factor - Temperature factor is the factor used for wood that is expected to be exposed to high temperatures for long periods of time.
Geometry Factor - Geometry Factor for connections or wood members with fasteners.
STEP 1: Convert Input(s) to Base Unit
Nominal Design Value for Lateral Loading: 20 Newton --> 20 Newton No Conversion Required
Load Duration Factor: 0.74 --> No Conversion Required
Wet Service Factor: 0.81 --> No Conversion Required
Temperature Factor: 0.8 --> No Conversion Required
Geometry Factor: 1.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z' = Z*CD*Cm*Ct*CΔ --> 20*0.74*0.81*0.8*1.5
Evaluating ... ...
Z' = 14.3856
STEP 3: Convert Result to Output's Unit
14.3856 Newton --> No Conversion Required
FINAL ANSWER
14.3856 Newton <-- Adjusted Design Value for Lateral Loading
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Himanshi Sharma
Bhilai Institute of Technology (BIT), Raipur
Himanshi Sharma has verified this Calculator and 800+ more calculators!

Adjustment of Design Values for Connections with Fasteners Calculators

Adjusted Value for Loading Parallel to Grain for Split Ring and Shear Plate Connectors
​ LaTeX ​ Go Adjusted Value for Loading Perpendicular to Grain = Nominal Design Value for Loading Parallel to Grain*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor*Penetration Depth Factor*Metal Side-Plate Factor
Adjusted Value for Loading Normal to Grain for Split Ring and Shear Plate Connectors
​ LaTeX ​ Go Adjusted Value for Loading Normal to Grain = Nominal Design Value for Loading Normal to Grain*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor*Penetration Depth Factor
Adjusted Design Value for Lateral Loading for Bolts
​ LaTeX ​ Go Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor
Adjusted Design Value for Withdrawal for Nails and Spikes
​ LaTeX ​ Go Adjusted Design Value for Withdrawal = Nominal Design Value for Withdrawal*Load Duration Factor*Wet Service Factor*Temperature Factor*Toenail Factor

Adjusted Design Value for Lateral Loading for Spike Grids Formula

​LaTeX ​Go
Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*Geometry Factor
Z' = Z*CD*Cm*Ct*CΔ

What is Lateral loading and different types of Loading on Fasteners?

Lateral loading is the continuous and repeated application of a load on an object or structural component in a horizontal direction or parallel to the x-axis. Lateral loading can cause a material to shear or bend in the direction of the force and ultimately lead to the failure of the material.
The types of loading on the fasteners may be divided into four classes: lateral loading, withdrawal, loading parallel to the grain, and loading perpendicular to the grain.

How to Calculate Adjusted Design Value for Lateral Loading for Spike Grids?

Adjusted Design Value for Lateral Loading for Spike Grids calculator uses Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*Geometry Factor to calculate the Adjusted Design Value for Lateral Loading, The Adjusted Design Value for Lateral Loading for Spike Grids formula is defined as the product of the nominal design value for lateral loading and other parameters such as load duration factor, wet service factor, temperature factor and geometry factor. Adjusted Design Value for Lateral Loading is denoted by Z' symbol.

How to calculate Adjusted Design Value for Lateral Loading for Spike Grids using this online calculator? To use this online calculator for Adjusted Design Value for Lateral Loading for Spike Grids, enter Nominal Design Value for Lateral Loading (Z), Load Duration Factor (CD), Wet Service Factor (Cm), Temperature Factor (Ct) & Geometry Factor (CΔ) and hit the calculate button. Here is how the Adjusted Design Value for Lateral Loading for Spike Grids calculation can be explained with given input values -> 14.3856 = 20*0.74*0.81*0.8*1.5.

FAQ

What is Adjusted Design Value for Lateral Loading for Spike Grids?
The Adjusted Design Value for Lateral Loading for Spike Grids formula is defined as the product of the nominal design value for lateral loading and other parameters such as load duration factor, wet service factor, temperature factor and geometry factor and is represented as Z' = Z*CD*Cm*Ct*CΔ or Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*Geometry Factor. Nominal Design Value for Lateral Loading for connections or wood members with fasteners. Design values are principles or beliefs that are adopted by a designer to guide their work, Load Duration Factor is based on the ability of wood to recover after a reasonable load has been applied for a given time, Wet Service Factor is used to signify wood that will not be used in a dry condition, Temperature factor is the factor used for wood that is expected to be exposed to high temperatures for long periods of time & Geometry Factor for connections or wood members with fasteners.
How to calculate Adjusted Design Value for Lateral Loading for Spike Grids?
The Adjusted Design Value for Lateral Loading for Spike Grids formula is defined as the product of the nominal design value for lateral loading and other parameters such as load duration factor, wet service factor, temperature factor and geometry factor is calculated using Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*Geometry Factor. To calculate Adjusted Design Value for Lateral Loading for Spike Grids, you need Nominal Design Value for Lateral Loading (Z), Load Duration Factor (CD), Wet Service Factor (Cm), Temperature Factor (Ct) & Geometry Factor (CΔ). With our tool, you need to enter the respective value for Nominal Design Value for Lateral Loading, Load Duration Factor, Wet Service Factor, Temperature Factor & Geometry Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Adjusted Design Value for Lateral Loading?
In this formula, Adjusted Design Value for Lateral Loading uses Nominal Design Value for Lateral Loading, Load Duration Factor, Wet Service Factor, Temperature Factor & Geometry Factor. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor*Diaphragm Factor*Toenail Factor
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!