Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry Factor
Z' = Z*Cm*CD*Ct*Cd*Ceg*Cg*CΔ
This formula uses 9 Variables
Variables Used
Adjusted Design Value for Lateral Loading - (Measured in Newton) - Adjusted design value for lateral loading is given in terms of nominal design values and adjustment factors.
Nominal Design Value for Lateral Loading - (Measured in Newton) - Nominal Design Value for Lateral Loading for connections or wood members with fasteners. Design values are principles or beliefs that are adopted by a designer to guide their work.
Wet Service Factor - Wet Service Factor is used to signify wood that will not be used in a dry condition.
Load Duration Factor - Load Duration Factor is based on the ability of wood to recover after a reasonable load has been applied for a given time.
Temperature Factor - Temperature factor is the factor used for wood that is expected to be exposed to high temperatures for long periods of time.
Penetration Depth Factor - Penetration Depth Factor for split ring and shear plate connectors is the analyzing area for resistivity measurement depends on several factors of the material. In no case should Cd exceed unity.
End Grain Factor - End Grain Factor is a factor used for wood design. End grain is the grain of wood seen when it is cut across the growth rings.
Group Action Factor - Group action factor for connections or wood members with the fasteners.
Geometry Factor - Geometry Factor for connections or wood members with fasteners.
STEP 1: Convert Input(s) to Base Unit
Nominal Design Value for Lateral Loading: 20 Newton --> 20 Newton No Conversion Required
Wet Service Factor: 0.81 --> No Conversion Required
Load Duration Factor: 0.74 --> No Conversion Required
Temperature Factor: 0.8 --> No Conversion Required
Penetration Depth Factor: 0.9 --> No Conversion Required
End Grain Factor: 0.75 --> No Conversion Required
Group Action Factor: 0.97 --> No Conversion Required
Geometry Factor: 1.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z' = Z*Cm*CD*Ct*Cd*Ceg*Cg*CΔ --> 20*0.81*0.74*0.8*0.9*0.75*0.97*1.5
Evaluating ... ...
Z' = 9.4189716
STEP 3: Convert Result to Output's Unit
9.4189716 Newton --> No Conversion Required
FINAL ANSWER
9.4189716 9.418972 Newton <-- Adjusted Design Value for Lateral Loading
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Adjustment of Design Values for Connections with Fasteners Calculators

Adjusted Value for Loading Parallel to Grain for Split Ring and Shear Plate Connectors
​ LaTeX ​ Go Adjusted Value for Loading Perpendicular to Grain = Nominal Design Value for Loading Parallel to Grain*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor*Penetration Depth Factor*Metal Side-Plate Factor
Adjusted Value for Loading Normal to Grain for Split Ring and Shear Plate Connectors
​ LaTeX ​ Go Adjusted Value for Loading Normal to Grain = Nominal Design Value for Loading Normal to Grain*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor*Penetration Depth Factor
Adjusted Design Value for Lateral Loading for Bolts
​ LaTeX ​ Go Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor
Adjusted Design Value for Withdrawal for Nails and Spikes
​ LaTeX ​ Go Adjusted Design Value for Withdrawal = Nominal Design Value for Withdrawal*Load Duration Factor*Wet Service Factor*Temperature Factor*Toenail Factor

Adjusted Design Value for Lateral Loading for Lag Screws Formula

​LaTeX ​Go
Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry Factor
Z' = Z*Cm*CD*Ct*Cd*Ceg*Cg*CΔ

What is Lateral loading and different types of Loading on Fasteners?

Lateral loading is the continuous and repeated application of a load on an object or structural component in a horizontal direction or parallel to the x-axis. Lateral loading can cause a material to shear or bend in the direction of the force and ultimately lead to the failure of the material.
The types of loading on the fasteners may be divided into four classes: lateral loading, withdrawal, loading parallel to the grain, and loading perpendicular to the grain.

What are Lag Screws?

A lag screw, known in the UK as a coach screw, is a sturdy screw often with an externally driven square or hex drive head. It features coarse threads and a tapered point. It's typically much more heavy-duty than conventional wood screws.

How to Calculate Adjusted Design Value for Lateral Loading for Lag Screws?

Adjusted Design Value for Lateral Loading for Lag Screws calculator uses Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry Factor to calculate the Adjusted Design Value for Lateral Loading, The Adjusted Design Value for Lateral Loading for Lag Screws formula is defined by the parameters, wet service factor, load duration factor, temperature factor, geometry factor, end grain factor, penetration depth factor, group action factor and nominal design value for lateral loading. Adjusted Design Value for Lateral Loading is denoted by Z' symbol.

How to calculate Adjusted Design Value for Lateral Loading for Lag Screws using this online calculator? To use this online calculator for Adjusted Design Value for Lateral Loading for Lag Screws, enter Nominal Design Value for Lateral Loading (Z), Wet Service Factor (Cm), Load Duration Factor (CD), Temperature Factor (Ct), Penetration Depth Factor (Cd), End Grain Factor (Ceg), Group Action Factor (Cg) & Geometry Factor (CΔ) and hit the calculate button. Here is how the Adjusted Design Value for Lateral Loading for Lag Screws calculation can be explained with given input values -> 9.418972 = 20*0.81*0.74*0.8*0.9*0.75*0.97*1.5.

FAQ

What is Adjusted Design Value for Lateral Loading for Lag Screws?
The Adjusted Design Value for Lateral Loading for Lag Screws formula is defined by the parameters, wet service factor, load duration factor, temperature factor, geometry factor, end grain factor, penetration depth factor, group action factor and nominal design value for lateral loading and is represented as Z' = Z*Cm*CD*Ct*Cd*Ceg*Cg*CΔ or Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry Factor. Nominal Design Value for Lateral Loading for connections or wood members with fasteners. Design values are principles or beliefs that are adopted by a designer to guide their work, Wet Service Factor is used to signify wood that will not be used in a dry condition, Load Duration Factor is based on the ability of wood to recover after a reasonable load has been applied for a given time, Temperature factor is the factor used for wood that is expected to be exposed to high temperatures for long periods of time, Penetration Depth Factor for split ring and shear plate connectors is the analyzing area for resistivity measurement depends on several factors of the material. In no case should Cd exceed unity, End Grain Factor is a factor used for wood design. End grain is the grain of wood seen when it is cut across the growth rings, Group action factor for connections or wood members with the fasteners & Geometry Factor for connections or wood members with fasteners.
How to calculate Adjusted Design Value for Lateral Loading for Lag Screws?
The Adjusted Design Value for Lateral Loading for Lag Screws formula is defined by the parameters, wet service factor, load duration factor, temperature factor, geometry factor, end grain factor, penetration depth factor, group action factor and nominal design value for lateral loading is calculated using Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry Factor. To calculate Adjusted Design Value for Lateral Loading for Lag Screws, you need Nominal Design Value for Lateral Loading (Z), Wet Service Factor (Cm), Load Duration Factor (CD), Temperature Factor (Ct), Penetration Depth Factor (Cd), End Grain Factor (Ceg), Group Action Factor (Cg) & Geometry Factor (CΔ). With our tool, you need to enter the respective value for Nominal Design Value for Lateral Loading, Wet Service Factor, Load Duration Factor, Temperature Factor, Penetration Depth Factor, End Grain Factor, Group Action Factor & Geometry Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Adjusted Design Value for Lateral Loading?
In this formula, Adjusted Design Value for Lateral Loading uses Nominal Design Value for Lateral Loading, Wet Service Factor, Load Duration Factor, Temperature Factor, Penetration Depth Factor, End Grain Factor, Group Action Factor & Geometry Factor. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry Factor
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor*Diaphragm Factor*Toenail Factor
  • Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!