Actual Volume of Refrigerant given Volumetric Efficiency Solution

STEP 0: Pre-Calculation Summary
Formula Used
Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor
Vs = ηv*Vp
This formula uses 3 Variables
Variables Used
Actual Volume of Refrigerant - (Measured in Cubic Meter) - The actual volume of Refrigerant is the volume occupied by the refrigerant in the compressor during the suction stroke.
Volumetric Efficiency of Compressor - Volumetric Efficiency of Compressor is the ratio of the actual volume of refrigerant passing through the compressor per cycle (Vs) to the stroke of the volume of the compressor (Vp).
Stroke Volume of Compressor - (Measured in Cubic Meter) - The stroke volume of compressor is the displacement volume of the piston, between the top dead center and the bottom dead center of the compressor.
STEP 1: Convert Input(s) to Base Unit
Volumetric Efficiency of Compressor: 0.68 --> No Conversion Required
Stroke Volume of Compressor: 1.5 Cubic Meter --> 1.5 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vs = ηv*Vp --> 0.68*1.5
Evaluating ... ...
Vs = 1.02
STEP 3: Convert Result to Output's Unit
1.02 Cubic Meter --> No Conversion Required
FINAL ANSWER
1.02 Cubic Meter <-- Actual Volume of Refrigerant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Vishwakarma Institute of Information Technology, Pune (VIIT Pune), Pune
Abhishek Dharmendra Bansile has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Volume Calculators

Actual volume of refrigerant
​ LaTeX ​ Go Actual Volume of Refrigerant = Total Volume of Refrigerant in Compressor-Expanded Clearance Volume
Actual Volume of Refrigerant given Volumetric Efficiency
​ LaTeX ​ Go Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor
Stroke Volume of Compressor given Volumetric efficiency
​ LaTeX ​ Go Stroke Volume of Compressor = Actual Volume of Refrigerant/Volumetric Efficiency of Compressor
Stroke Volume of Compressor
​ LaTeX ​ Go Stroke Volume of Compressor = Total Volume of Refrigerant in Compressor-Clearance Volume

Actual Volume of Refrigerant given Volumetric Efficiency Formula

​LaTeX ​Go
Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor
Vs = ηv*Vp

What are the factors which affects the volumetric Efficiency of Compressor?

Volumetric efficiency depends on ambient pressure and temperature, suction pressure and temperature, the ratio of clearance to swept volume, and pressure limits. Volumetric efficiency increases with a decrease in pressure ratio in the compressor.

How to Calculate Actual Volume of Refrigerant given Volumetric Efficiency?

Actual Volume of Refrigerant given Volumetric Efficiency calculator uses Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor to calculate the Actual Volume of Refrigerant, Actual Volume of Refrigerant given Volumetric Efficiency formula is defined as the volume of refrigerant that is actually available for cooling, which is affected by the volumetric efficiency of the refrigeration system, a key factor in determining the system's overall performance and capacity. Actual Volume of Refrigerant is denoted by Vs symbol.

How to calculate Actual Volume of Refrigerant given Volumetric Efficiency using this online calculator? To use this online calculator for Actual Volume of Refrigerant given Volumetric Efficiency, enter Volumetric Efficiency of Compressor v) & Stroke Volume of Compressor (Vp) and hit the calculate button. Here is how the Actual Volume of Refrigerant given Volumetric Efficiency calculation can be explained with given input values -> 1.02 = 0.68*1.5.

FAQ

What is Actual Volume of Refrigerant given Volumetric Efficiency?
Actual Volume of Refrigerant given Volumetric Efficiency formula is defined as the volume of refrigerant that is actually available for cooling, which is affected by the volumetric efficiency of the refrigeration system, a key factor in determining the system's overall performance and capacity and is represented as Vs = ηv*Vp or Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor. Volumetric Efficiency of Compressor is the ratio of the actual volume of refrigerant passing through the compressor per cycle (Vs) to the stroke of the volume of the compressor (Vp) & The stroke volume of compressor is the displacement volume of the piston, between the top dead center and the bottom dead center of the compressor.
How to calculate Actual Volume of Refrigerant given Volumetric Efficiency?
Actual Volume of Refrigerant given Volumetric Efficiency formula is defined as the volume of refrigerant that is actually available for cooling, which is affected by the volumetric efficiency of the refrigeration system, a key factor in determining the system's overall performance and capacity is calculated using Actual Volume of Refrigerant = Volumetric Efficiency of Compressor*Stroke Volume of Compressor. To calculate Actual Volume of Refrigerant given Volumetric Efficiency, you need Volumetric Efficiency of Compressor v) & Stroke Volume of Compressor (Vp). With our tool, you need to enter the respective value for Volumetric Efficiency of Compressor & Stroke Volume of Compressor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Actual Volume of Refrigerant?
In this formula, Actual Volume of Refrigerant uses Volumetric Efficiency of Compressor & Stroke Volume of Compressor. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Actual Volume of Refrigerant = Total Volume of Refrigerant in Compressor-Expanded Clearance Volume
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!