Actual Solid Loading Rate of Circular Settling Tanks Solution

STEP 0: Pre-Calculation Summary
Formula Used
Solid Loading Rate = Solid Processed/Surface Area
SLr = Sp/SA
This formula uses 3 Variables
Variables Used
Solid Loading Rate - (Measured in Kilogram per Second Square Meter) - Solid Loading Rate is the amount of solids applied per unit area of a treatment process, such as a clarifier, typically measured in kilograms per square meter per day (kg/m²/day).
Solid Processed - (Measured in Kilogram per Second) - Solid Processed is the total quantity or volume of solids treated, settled, or removed from the wastewater over a specific period, typically measured in kilograms, tons, or cubic meters.
Surface Area - (Measured in Square Meter) - Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
STEP 1: Convert Input(s) to Base Unit
Solid Processed: 80.01 Kilogram per Day --> 0.000926041666666667 Kilogram per Second (Check conversion ​here)
Surface Area: 4 Square Meter --> 4 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
SLr = Sp/SA --> 0.000926041666666667/4
Evaluating ... ...
SLr = 0.000231510416666667
STEP 3: Convert Result to Output's Unit
0.000231510416666667 Kilogram per Second Square Meter -->20.0025 kilogram per Day Square Meter (Check conversion ​here)
FINAL ANSWER
20.0025 kilogram per Day Square Meter <-- Solid Loading Rate
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Circular Settling Tank Calculators

Design Surface Loading Rate given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Loading Rate = (Peak Discharge/Surface Area)
Peak Discharge given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Peak Discharge = (Surface Area*Surface Loading Rate)
Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Area = (Peak Discharge/Surface Loading Rate)
Peak Discharge in Circular Settling Tanks
​ LaTeX ​ Go Peak Discharge = Average Daily Load*Peaking Factor

Actual Solid Loading Rate of Circular Settling Tanks Formula

​LaTeX ​Go
Solid Loading Rate = Solid Processed/Surface Area
SLr = Sp/SA

What is Solid Loading Rate?

The Solid Loading Rate is the number of gallons of wastewater passing over 1 ft2 of tank per day. Plant designs generally use a surface loading rate of 300 to 1200 gpd/ft2.

How to Calculate Actual Solid Loading Rate of Circular Settling Tanks?

Actual Solid Loading Rate of Circular Settling Tanks calculator uses Solid Loading Rate = Solid Processed/Surface Area to calculate the Solid Loading Rate, The Actual Solid Loading Rate of Circular Settling Tanks is defined as the real or observed rate at which solids are introduced into the tank, typically measured in kilograms per square meter per day (kg/m²/day). Solid Loading Rate is denoted by SLr symbol.

How to calculate Actual Solid Loading Rate of Circular Settling Tanks using this online calculator? To use this online calculator for Actual Solid Loading Rate of Circular Settling Tanks, enter Solid Processed (Sp) & Surface Area (SA) and hit the calculate button. Here is how the Actual Solid Loading Rate of Circular Settling Tanks calculation can be explained with given input values -> 2.6E+6 = 0.000926041666666667/4.

FAQ

What is Actual Solid Loading Rate of Circular Settling Tanks?
The Actual Solid Loading Rate of Circular Settling Tanks is defined as the real or observed rate at which solids are introduced into the tank, typically measured in kilograms per square meter per day (kg/m²/day) and is represented as SLr = Sp/SA or Solid Loading Rate = Solid Processed/Surface Area. Solid Processed is the total quantity or volume of solids treated, settled, or removed from the wastewater over a specific period, typically measured in kilograms, tons, or cubic meters & Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
How to calculate Actual Solid Loading Rate of Circular Settling Tanks?
The Actual Solid Loading Rate of Circular Settling Tanks is defined as the real or observed rate at which solids are introduced into the tank, typically measured in kilograms per square meter per day (kg/m²/day) is calculated using Solid Loading Rate = Solid Processed/Surface Area. To calculate Actual Solid Loading Rate of Circular Settling Tanks, you need Solid Processed (Sp) & Surface Area (SA). With our tool, you need to enter the respective value for Solid Processed & Surface Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Solid Loading Rate?
In this formula, Solid Loading Rate uses Solid Processed & Surface Area. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Solid Loading Rate = (Maximum Solids/Surface Area)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!