Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted by Belt = Design Power of Belt Drive/Load Correction Factor
Pt = Pd/Fa
This formula uses 3 Variables
Variables Used
Power Transmitted by Belt - (Measured in Watt) - Power Transmitted by Belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Design Power of Belt Drive - (Measured in Watt) - Design Power of Belt Drive is defined as the power transmitted on the basis of the design.
Load Correction Factor - Load Correction Factor increases the power factor of a load, improving efficiency for the distribution system to which it is attached.
STEP 1: Convert Input(s) to Base Unit
Design Power of Belt Drive: 7.41 Kilowatt --> 7410 Watt (Check conversion ​here)
Load Correction Factor: 1.15 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pt = Pd/Fa --> 7410/1.15
Evaluating ... ...
Pt = 6443.47826086957
STEP 3: Convert Result to Output's Unit
6443.47826086957 Watt -->6.44347826086957 Kilowatt (Check conversion ​here)
FINAL ANSWER
6.44347826086957 6.443478 Kilowatt <-- Power Transmitted by Belt
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Maximum Power Conditions Calculators

Optimum Velocity of Belt for Maximum Power Transmission
​ Go Optimum Velocity of Belt = sqrt(Initial Tension in Belt/(3*Mass of Meter Length of Belt))
Initial Tension in Belt Drive
​ Go Initial Tension in Belt = (Belt Tension on Tight Side+Belt Tension on Loose Side)/2
Belt Tension in Tight Side of Belt given Initial Tension in Belt
​ Go Belt Tension on Tight Side = 2*Initial Tension in Belt-Belt Tension on Loose Side
Belt Tension in Loose Side of Belt given Initial Tension in Belt
​ Go Belt Tension on Loose Side = 2*Initial Tension in Belt-Belt Tension on Tight Side

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Formula

​Go
Power Transmitted by Belt = Design Power of Belt Drive/Load Correction Factor
Pt = Pd/Fa

Define Flat Belts?

A flat belt is a belt with a flat surface, usually evenly textured on both sides, used in a pulley system. In conveyer belt construction, the flat belt can be used as a single broad belt on an assembly line or as part of an array of webbed belts.

How to Calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose calculator uses Power Transmitted by Belt = Design Power of Belt Drive/Load Correction Factor to calculate the Power Transmitted by Belt, The Actual Power Transmitted given Power Transmitted by Flat for Design Purpose formula is defined as the actual power transmitted by the flat belts after all losses in given power applications. Power Transmitted by Belt is denoted by Pt symbol.

How to calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose using this online calculator? To use this online calculator for Actual Power Transmitted given Power Transmitted by Flat for Design Purpose, enter Design Power of Belt Drive (Pd) & Load Correction Factor (Fa) and hit the calculate button. Here is how the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose calculation can be explained with given input values -> 0.006443 = 7410/1.15.

FAQ

What is Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?
The Actual Power Transmitted given Power Transmitted by Flat for Design Purpose formula is defined as the actual power transmitted by the flat belts after all losses in given power applications and is represented as Pt = Pd/Fa or Power Transmitted by Belt = Design Power of Belt Drive/Load Correction Factor. Design Power of Belt Drive is defined as the power transmitted on the basis of the design & Load Correction Factor increases the power factor of a load, improving efficiency for the distribution system to which it is attached.
How to calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?
The Actual Power Transmitted given Power Transmitted by Flat for Design Purpose formula is defined as the actual power transmitted by the flat belts after all losses in given power applications is calculated using Power Transmitted by Belt = Design Power of Belt Drive/Load Correction Factor. To calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose, you need Design Power of Belt Drive (Pd) & Load Correction Factor (Fa). With our tool, you need to enter the respective value for Design Power of Belt Drive & Load Correction Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!