Activation Energy given Slope of Line between LnK and Temperature Inverse Solution

STEP 0: Pre-Calculation Summary
Formula Used
Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R])
Ea = -(mslope*[R])
This formula uses 1 Constants, 2 Variables
Constants Used
[R] - Universal gas constant Value Taken As 8.31446261815324
Variables Used
Activation Energy - (Measured in Joule Per Mole) - Activation Energy is the minimum amount of energy that is required to activate atoms or molecules to a condition in which they can undergo chemical transformation.
Slope of Line B/w Ln K and 1/T - (Measured in Kelvin) - The slope of Line B/w Ln K and 1/T is defined as when the Lnk (rate constant) is plotted versus the inverse of the temperature (kelvin), the slope is a straight line.
STEP 1: Convert Input(s) to Base Unit
Slope of Line B/w Ln K and 1/T: -0.707 Kelvin --> -0.707 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ea = -(mslope*[R]) --> -((-0.707)*[R])
Evaluating ... ...
Ea = 5.87832507103434
STEP 3: Convert Result to Output's Unit
5.87832507103434 Joule Per Mole --> No Conversion Required
FINAL ANSWER
5.87832507103434 5.878325 Joule Per Mole <-- Activation Energy
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Torsha_Paul
University of Calcutta (CU), Kolkata
Torsha_Paul has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 900+ more calculators!

Temperature Coefficient Calculators

Rate Constant at Temperature 2
​ LaTeX ​ Go Rate Constant at Temperature 2 = ((Rate Constant at Temperature 1)*(Temperature Coefficient)^((Temperature 2-Temperature 1)/10))
Temperature Coefficient using Rate Constant
​ LaTeX ​ Go Temperature Coefficient = Rate Constant at (T+10)°C/Rate Constant at T° C
Activation Energy given Slope of Line between Log K and Temp Inverse
​ LaTeX ​ Go Activation Energy = -2.303*[R]*Slope of Line Between Log K and 1/T
Activation Energy given Slope of Line between LnK and Temperature Inverse
​ LaTeX ​ Go Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R])

Activation Energy given Slope of Line between LnK and Temperature Inverse Formula

​LaTeX ​Go
Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R])
Ea = -(mslope*[R])

What is Activation Energy ?

Activation energy, is the minimum amount of energy that is required to activate atoms or molecules to a condition in which they can undergo a chemical transformation or physical transport.

How to Calculate Activation Energy given Slope of Line between LnK and Temperature Inverse?

Activation Energy given Slope of Line between LnK and Temperature Inverse calculator uses Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R]) to calculate the Activation Energy, Activation Energy given Slope of Line between LnK and Temperature Inverse is defined as when the Lnk (rate constant) is plotted versus the inverse of the temperature (kelvin), the slope is a straight line. Activation Energy is denoted by Ea symbol.

How to calculate Activation Energy given Slope of Line between LnK and Temperature Inverse using this online calculator? To use this online calculator for Activation Energy given Slope of Line between LnK and Temperature Inverse, enter Slope of Line B/w Ln K and 1/T (mslope) and hit the calculate button. Here is how the Activation Energy given Slope of Line between LnK and Temperature Inverse calculation can be explained with given input values -> 5.878325 = -((-0.707)*[R]).

FAQ

What is Activation Energy given Slope of Line between LnK and Temperature Inverse?
Activation Energy given Slope of Line between LnK and Temperature Inverse is defined as when the Lnk (rate constant) is plotted versus the inverse of the temperature (kelvin), the slope is a straight line and is represented as Ea = -(mslope*[R]) or Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R]). The slope of Line B/w Ln K and 1/T is defined as when the Lnk (rate constant) is plotted versus the inverse of the temperature (kelvin), the slope is a straight line.
How to calculate Activation Energy given Slope of Line between LnK and Temperature Inverse?
Activation Energy given Slope of Line between LnK and Temperature Inverse is defined as when the Lnk (rate constant) is plotted versus the inverse of the temperature (kelvin), the slope is a straight line is calculated using Activation Energy = -(Slope of Line B/w Ln K and 1/T*[R]). To calculate Activation Energy given Slope of Line between LnK and Temperature Inverse, you need Slope of Line B/w Ln K and 1/T (mslope). With our tool, you need to enter the respective value for Slope of Line B/w Ln K and 1/T and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Activation Energy?
In this formula, Activation Energy uses Slope of Line B/w Ln K and 1/T. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Activation Energy = -2.303*[R]*Slope of Line Between Log K and 1/T
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp