Absorption Coefficient Solution

STEP 0: Pre-Calculation Summary
Formula Used
Absorption Coefficient = (-1/Sample Thickness)*ln(Absorbed Power/Incident Power)
α = (-1/b)*ln(Pabs/Pi)
This formula uses 1 Functions, 4 Variables
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
Variables Used
Absorption Coefficient - (Measured in 1 per Meter) - Absorption Coefficient determines how far into a material, light of a particular wavelength can penetrate before it is absorbed.
Sample Thickness - (Measured in Meter) - Sample Thickness is defined as the total distance between the two planes of the sample taken.
Absorbed Power - (Measured in Watt) - Absorbed Power is defined as the power consumed by a solid state device while operating.
Incident Power - (Measured in Watt) - Incident Power is the intensity of the incident light ray striking the surface.
STEP 1: Convert Input(s) to Base Unit
Sample Thickness: 0.46 Micrometer --> 4.6E-07 Meter (Check conversion ​here)
Absorbed Power: 0.11 Watt --> 0.11 Watt No Conversion Required
Incident Power: 0.22 Watt --> 0.22 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
α = (-1/b)*ln(Pabs/Pi) --> (-1/4.6E-07)*ln(0.11/0.22)
Evaluating ... ...
α = 1506841.69686945
STEP 3: Convert Result to Output's Unit
1506841.69686945 1 per Meter -->15068.4169686945 1 per Centimeter (Check conversion ​here)
FINAL ANSWER
15068.4169686945 15068.42 1 per Centimeter <-- Absorption Coefficient
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Yada Sai Pranay
Indian Institute of Information Technology Design and Manufacturing ((IIIT D&M Kancheepuram)), Chennai
Yada Sai Pranay has created this Calculator and 4 more calculators!
Verifier Image
Verified by Saiju Shah
Jayawantrao Sawant College of Engineering (JSCOE), Pune
Saiju Shah has verified this Calculator and 25+ more calculators!

SSD Junction Calculators

Junction Capacitance
​ Go Junction Capacitance = (Junction Area/2)*sqrt((2*[Charge-e]*Constant Length Offset*Doping Concentration of Base)/(Source Voltage-Source Voltage 1))
Series Resistance in P-type
​ Go Series Resistance in P Junction = ((Source Voltage-Junction Voltage)/Electric Current)-Series Resistance in N Junction
Junction Voltage
​ Go Junction Voltage = Source Voltage-(Series Resistance in P Junction+Series Resistance in N Junction)*Electric Current
N-Type Width
​ Go Charge Penetration N-type = Total Acceptor Charge/(Junction Area*Acceptor Concentration*[Charge-e])

Absorption Coefficient Formula

Absorption Coefficient = (-1/Sample Thickness)*ln(Absorbed Power/Incident Power)
α = (-1/b)*ln(Pabs/Pi)

What is an Absorption Coefficient?

The absorption coefficient determines how far into a material light of a particular wavelength can penetrate before it is absorbed. In a material with a low absorption coefficient, light is only poorly absorbed, and if the material is thin enough, it will appear transparent to that wavelength. Absorption coefficient has the units [cm^-1]

How to Calculate Absorption Coefficient?

Absorption Coefficient calculator uses Absorption Coefficient = (-1/Sample Thickness)*ln(Absorbed Power/Incident Power) to calculate the Absorption Coefficient, Absorption Coefficient determines how far into a material, light of a particular wavelength can penetrate before it is absorbed. Absorption Coefficient is denoted by α symbol.

How to calculate Absorption Coefficient using this online calculator? To use this online calculator for Absorption Coefficient, enter Sample Thickness (b), Absorbed Power (Pabs) & Incident Power (Pi) and hit the calculate button. Here is how the Absorption Coefficient calculation can be explained with given input values -> 150.6842 = (-1/4.6E-07)*ln(0.11/0.22).

FAQ

What is Absorption Coefficient?
Absorption Coefficient determines how far into a material, light of a particular wavelength can penetrate before it is absorbed and is represented as α = (-1/b)*ln(Pabs/Pi) or Absorption Coefficient = (-1/Sample Thickness)*ln(Absorbed Power/Incident Power). Sample Thickness is defined as the total distance between the two planes of the sample taken, Absorbed Power is defined as the power consumed by a solid state device while operating & Incident Power is the intensity of the incident light ray striking the surface.
How to calculate Absorption Coefficient?
Absorption Coefficient determines how far into a material, light of a particular wavelength can penetrate before it is absorbed is calculated using Absorption Coefficient = (-1/Sample Thickness)*ln(Absorbed Power/Incident Power). To calculate Absorption Coefficient, you need Sample Thickness (b), Absorbed Power (Pabs) & Incident Power (Pi). With our tool, you need to enter the respective value for Sample Thickness, Absorbed Power & Incident Power and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!