Absolute Humidity of Air at Initial Air Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti)
Yg = (((h1*(ti-Tl))-hg*(Tg-ti))/(ky*hfg))+Yi
This formula uses 9 Variables
Variables Used
Absolute Humidity of Air(tg) - Absolute Humidity of Air(tg) at the initial air temperature.
Liquid Phase Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - Liquid Phase Heat Transfer Coefficient is the heat transfer in liquid per unit area in kelvin.
Inside Temperature - (Measured in Kelvin) - Inside Temperature is the temperature of air present inside.
Liquid layer temperature - Liquid layer temperature is defined as the temperature of the flowing liquid layer in dehumidification.
Gas Phase Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - Gas Phase Heat Transfer Coefficient is the heat transfer in gas per unit area in kelvin.
Bulk Gas Temperature - Bulk gas temperature is adiabatic mixing of the gas from a given cross section of duct will result in some equilibrium temperature that accurately reflects average temperature of the moving fluid.
Gas Phase Mass Transfer Coefficient - (Measured in Mole per Second Square Meter) - Gas phase mass transfer coefficient is a diffusion rate constant that relates the mass transfer rate, mass transfer area, and concentration change as driving force.
Enthalpy of Evaporation - (Measured in Joule per Kilogram K) - Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Absolute Humidity (ti) - Absolute humidity (ti) is the quality of water vapor in the wet air of unit volume at temperature ti.
STEP 1: Convert Input(s) to Base Unit
Liquid Phase Heat Transfer Coefficient: 10.8 Watt per Square Meter per Kelvin --> 10.8 Watt per Square Meter per Kelvin No Conversion Required
Inside Temperature: 353 Kelvin --> 353 Kelvin No Conversion Required
Liquid layer temperature: 20 --> No Conversion Required
Gas Phase Heat Transfer Coefficient: 40 Watt per Square Meter per Kelvin --> 40 Watt per Square Meter per Kelvin No Conversion Required
Bulk Gas Temperature: 100 --> No Conversion Required
Gas Phase Mass Transfer Coefficient: 90 Mole per Second Square Meter --> 90 Mole per Second Square Meter No Conversion Required
Enthalpy of Evaporation: 80 Joule per Kilogram K --> 80 Joule per Kilogram K No Conversion Required
Absolute Humidity (ti): 50.7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Yg = (((h1*(ti-Tl))-hg*(Tg-ti))/(ky*hfg))+Yi --> (((10.8*(353-20))-40*(100-353))/(90*80))+50.7
Evaluating ... ...
Yg = 52.6050555555556
STEP 3: Convert Result to Output's Unit
52.6050555555556 --> No Conversion Required
FINAL ANSWER
52.6050555555556 52.60506 <-- Absolute Humidity of Air(tg)
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has verified this Calculator and 400+ more calculators!

Heat Transfer and Psychrometry Calculators

Absolute Humidity of Air at Initial Air Temperature
​ LaTeX ​ Go Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti)
Heat Flux
​ LaTeX ​ Go Heat Flux = Thermal Conductivity of Fin*Temperature of Conductor/Length of Conductor
Diameter of Rod Circular Fin given Area of Cross-Section
​ LaTeX ​ Go Diameter of Circular Rod = sqrt((Cross-sectional area*4)/pi)
Characteristic Length for Lumped System
​ LaTeX ​ Go Characteristic Length = (Volume)/(Area)

Absolute Humidity of Air at Initial Air Temperature Formula

​LaTeX ​Go
Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti)
Yg = (((h1*(ti-Tl))-hg*(Tg-ti))/(ky*hfg))+Yi

What is humidification?

Humidification is the process in which the moisture or water vapor or humidity is added to the air. Common equipment used in this process is a humidifier. Dehumidification as the term suggests, is the opposite of humidification since dehumidification means removing the moisture from the air. Common equipment used in this process is a dehumidifier.
Humidity is the presence of water vapor or moisture in the air, while relative humidity, on the other hand, is the comparison of the actual moisture or water vapor in the air vs. the total water vapor or moisture that the air can handle.

How to Calculate Absolute Humidity of Air at Initial Air Temperature?

Absolute Humidity of Air at Initial Air Temperature calculator uses Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti) to calculate the Absolute Humidity of Air(tg), The Absolute humidity of air at initial air temperature formula is defined as the amount of air that is present in the vapor at initial air temperature. Absolute Humidity of Air(tg) is denoted by Yg symbol.

How to calculate Absolute Humidity of Air at Initial Air Temperature using this online calculator? To use this online calculator for Absolute Humidity of Air at Initial Air Temperature, enter Liquid Phase Heat Transfer Coefficient (h1), Inside Temperature (ti), Liquid layer temperature (Tl), Gas Phase Heat Transfer Coefficient (hg), Bulk Gas Temperature (Tg), Gas Phase Mass Transfer Coefficient (ky), Enthalpy of Evaporation (hfg) & Absolute Humidity (ti) (Yi) and hit the calculate button. Here is how the Absolute Humidity of Air at Initial Air Temperature calculation can be explained with given input values -> 52.60506 = (((10.8*(353-20))-40*(100-353))/(90*80))+50.7.

FAQ

What is Absolute Humidity of Air at Initial Air Temperature?
The Absolute humidity of air at initial air temperature formula is defined as the amount of air that is present in the vapor at initial air temperature and is represented as Yg = (((h1*(ti-Tl))-hg*(Tg-ti))/(ky*hfg))+Yi or Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti). Liquid Phase Heat Transfer Coefficient is the heat transfer in liquid per unit area in kelvin, Inside Temperature is the temperature of air present inside, Liquid layer temperature is defined as the temperature of the flowing liquid layer in dehumidification, Gas Phase Heat Transfer Coefficient is the heat transfer in gas per unit area in kelvin, Bulk gas temperature is adiabatic mixing of the gas from a given cross section of duct will result in some equilibrium temperature that accurately reflects average temperature of the moving fluid, Gas phase mass transfer coefficient is a diffusion rate constant that relates the mass transfer rate, mass transfer area, and concentration change as driving force, Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas & Absolute humidity (ti) is the quality of water vapor in the wet air of unit volume at temperature ti.
How to calculate Absolute Humidity of Air at Initial Air Temperature?
The Absolute humidity of air at initial air temperature formula is defined as the amount of air that is present in the vapor at initial air temperature is calculated using Absolute Humidity of Air(tg) = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))+Absolute Humidity (ti). To calculate Absolute Humidity of Air at Initial Air Temperature, you need Liquid Phase Heat Transfer Coefficient (h1), Inside Temperature (ti), Liquid layer temperature (Tl), Gas Phase Heat Transfer Coefficient (hg), Bulk Gas Temperature (Tg), Gas Phase Mass Transfer Coefficient (ky), Enthalpy of Evaporation (hfg) & Absolute Humidity (ti) (Yi). With our tool, you need to enter the respective value for Liquid Phase Heat Transfer Coefficient, Inside Temperature, Liquid layer temperature, Gas Phase Heat Transfer Coefficient, Bulk Gas Temperature, Gas Phase Mass Transfer Coefficient, Enthalpy of Evaporation & Absolute Humidity (ti) and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!