Download Connectors and Stiffeners in Bridges PDF

Related PDFs (7)

Cable System, Sag and Drainage on Bridges
Formulas : 17   Size : 349 kb
Composite Construction in Highway Bridges
Formulas : 22   Size : 378 kb
General Relation for Suspension Cables
Formulas : 17   Size : 327 kb
Load Factor Design (LFD)
Formulas : 28   Size : 426 kb
Load, Stress and Fasteners
Formulas : 22   Size : 410 kb
Number of Connectors in Bridges
Formulas : 29   Size : 411 kb
Parabolic Cable Tension and Length
Formulas : 12   Size : 307 kb

Contents of the Connectors and Stiffeners in Bridges PDF

List of 34 Connectors and Stiffeners in Bridges Formulas

28-day Compressive Strength given Ultimate Shear Connector Strength for Welded Studs
28-day Compressive Strength of Concrete given Force in Slab
28-day Compressive Strength of Concrete given Ultimate Shear Connector Strength for Channels
Actual Stiffener Spacing for Minimum Moment of Inertia of Transverse Stiffener
Area of Longitudinal Reinforcing given Force in Slab at Maximum Negative Moments
Average Channel Flange Thickness given Ultimate Shear Connector Strength for Channels
Channel Length given Ultimate Shear Connector Strength for Channels
Channel Web Thickness given Ultimate Shear Connector Strength for Channels
Diameter of Connector given Ultimate Shear Connector Strength for Welded Studs
Effective Concrete Area given Force in Slab
Elastic Modulus of Concrete given Ultimate Shear Connector Strength for Welded Studs
Force in Slab at Maximum Negative Moments given Minimum Number of Connectors for Bridges
Force in Slab at Maximum Negative Moments given Reinforcing Steel Yield Strength
Force in Slab at Maximum Positive Moments given Minimum Number of Connectors for Bridges
Force in Slab given Effective Concrete Area
Force in Slab given Number of Connectors in Bridges
Force in Slab given Total Area of Steel Section
Minimum Moment of Inertia of Transverse Stiffener
Minimum Number of Connectors for Bridges
Moment of Inertia of Longitudinal Stiffeners
Number of Connectors in Bridges
Reduction Factor given Minimum Number of Connectors in Bridges
Reduction Factor given Number of Connectors in Bridges
Reinforcing Steel Yield Strength given Force in Slab at Maximum Negative Moments
Shear Capacity for Flexural Members
Shear Capacity for Girders with Transverse Stiffeners
Steel Yield Strength given Total Area of Steel Section
Total Area of Steel Section given Force in Slab
Ultimate Shear Connector Strength for Channels
Ultimate Shear Connector Strength given Minimum Number of Connectors in Bridges
Ultimate Shear Connector Strength given Number of Connectors in Bridges
Ultimate Shear Strength for Welded Studs
Web Thickness for Minimum Moment of Inertia of Transverse Stiffener
Web Thickness given Moment of Inertia of Longitudinal Stiffeners

Variables used in Connectors and Stiffeners in Bridges PDF

  1. a Clear Distance between Transverse Stiffeners (Millimeter)
  2. Aconcrete Effective Concrete Area (Square Millimeter)
  3. ao Actual Stiffener Spacing (Millimeter)
  4. Ao Actual Distance between Transverse Stiffeners (Millimeter)
  5. Ast Area of Steel Reinforcement (Square Millimeter)
  6. bw Breadth of Web (Millimeter)
  7. C Shear Buckling Coefficient C
  8. d Depth of Cross Section (Millimeter)
  9. D Clear Distance between Flanges (Millimeter)
  10. dstud Stud Diameter (Millimeter)
  11. E Modulus Elasticity of Concrete (Megapascal)
  12. fc 28 Day Compressive Strength of Concrete (Megapascal)
  13. fy Yield Strength of Steel (Megapascal)
  14. h Average Flange Thickness (Millimeter)
  15. H Cross Section's Height (Millimeter)
  16. I Moment of Inertia (Millimeter⁴)
  17. J Constant
  18. N No of Connector in Bridge
  19. P3 Force in Slab at Negative Moment Point (Kilonewton)
  20. Pon slab Slab Force (Kilonewton)
  21. Sultimate Ultimate Shear Connector Stress (Kilonewton)
  22. t Web Thickness (Millimeter)
  23. Vu Shear Capacity (Kilonewton)
  24. w Channel Length (Millimeter)
  25. Φ Reduction Factor

Constants, Functions and Measurements used in Connectors and Stiffeners in Bridges PDF

  1. Function: sqrt, sqrt(Number)
    A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
  2. Measurement: Length in Millimeter (mm)
    Length Unit Conversion
  3. Measurement: Area in Square Millimeter (mm²)
    Area Unit Conversion
  4. Measurement: Pressure in Megapascal (MPa)
    Pressure Unit Conversion
  5. Measurement: Force in Kilonewton (kN)
    Force Unit Conversion
  6. Measurement: Second Moment of Area in Millimeter⁴ (mm⁴)
    Second Moment of Area Unit Conversion
  7. Measurement: Stress in Megapascal (MPa)
    Stress Unit Conversion

Free Connectors and Stiffeners in Bridges PDF

Get Free Connectors and Stiffeners in Bridges PDF for Download today. Examples are included after each Formula with a link to a live Calculator! All the Formulas and Calculators support Unit Conversion as well. This PDF features 34 calculators from Civil. Inside, you'll discover a list of formulas such as Number of Connectors in Bridges, Force in Slab given Number of Connectors in Bridges and 34 more formulas!. The Variables, Functions and Constants are summarized at the end. Explore and share Connectors and Stiffeners in Bridges PDFs!

Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp